Tuesday, 24 November 2026

 Sonoff S26 Type G Smartplug Easy Repair

Sonoff Smartplug S26 UK Type


It's been a good while since my last blog post. The reason is simple: AI. Most of my posts are actually on software and these have been mostly superceded by Claude, ChatGPT, Gemini, Kimi, etc which makes posts on software kind of redundant. So, the new direction of this blog is going to be hardware.

The Sonoff S26 Smartplug is unremarkable but it works with Google Home so I can voice-activate it from my phone using Gemini. It is also cheap and cheerful and I have found it to be reliable. More reliable in fact than Google devices like Chromecast or Google Home Mini smart speaker which tend to become abandonware after a few years while Sonoff server support has been consistent. The case for repair is simply the devil I know, ie ITEAD has discontinued the S26 and replaced it with the S60.

Sonoff S60

After years of daily switching my S26 dropped out of the WiFi hotspot but otherwise seemed OK. It would not pair when reset, and that ITEAD_XXX hotspot no longer came up in pairing mode. The problem turned out to be a failing 3.3V power rail to the ESP8266 module. Specifically a 330uF 16V electrolytic capacitor. It showed no sign of damage or bulging, but it was telling that it was a VENT JWCO, ie not a low-ESR capacitor normally needed for the output rail of a switched mode power supply (SMPS).

Sonoff S26 with the cover off showing the faulty 330uF 16V electrolytic capacitor

I replaced it with a VENT JWCO low-ESR 220uF 25V electrolytic capacitor and that ITEAD_XXX hotspot came right back and I was able to pair it again using the eWeLink app.

Oh, one more thing: the cover is held on by 3 screws two of which are almost hidden by a keyed detachable white plastic ring around the plug pins. 

IMPORTANT: This device exposes lethal mains voltages when dismantled. DO NOT ATTEMPT REPAIR IF YOU ARE NOT A QUALIFIED technician.

Also, faulty switch-mode power supplies can react violently (flames, small explosions, smoke, etc) to mains power. I always test repair items using an isolation transformer ie a 230V to 230V 1:1 transformer rated at only 40W fitted with a separate ELCB (earth-leakage circuit breaker). 40W is enough to power up but will simply sag harmlessly if there is a fault. BTW 40W is enough to deliver a fatal electric shock, hence the extra ELCB.

You can just about see the hidden mounting screws underneath the Live and Neutral pins. That round ring can be pulled out to expose the screws.


Happy Trails